TC3300/2- 10 program 4 segment Kiln Controller

Stock Code: TC3300-2
3 In Stock for despatch
547.93£547.93 (inc VAT) per EACH
£456.61 (exc VAT)
Quantity: - +

TC3300/2 Controller 10 Program - 4 Segments

Description
10 Program controller with Delay, 4 Ramps and 4 Dwells (ideal for firing most large or complexceramics where both heating and cooling speeds are required).
TC3300/2 features
Delay start facility - 0 - 99 hours 59 minutes.
Segment 1.
Heating Ramp 1 - 1 to 999°C per hour or FULL powerto 'first set-point'.
Set-point 1 - 1 to1300°C or to factory pre-set limit.
Soak Period / dwell- 0 to99hours 59 minutes.
Segment 2-4 - As segment 1 then End (Automatic switch off).

Other features:-
Constant temperature readout.
Power usage indicator.
Program pause function.
Wall mounting.
Power interruption restart within 100°C temperature fall.
Over temperature security contactor output.
Plug and go facility via Harting plug.
Keyboard lockable.
Thermo coupleType - S,R,K or N (Standard factory preset UK to R type).
Range R/S -20 to 1600°C °F - K/N 0 to1300°C °F.
Resolution 1 Degree.
Accuracy +/- 0.1% FSD +/- 1 digit.
Control Adaptive PID.
Supply 207-265 VAC- 50/60Hz - 6VA max.
Output 230v AC.
Dimensions 120x 190x 78mm.

CONTROLLER TERMINOLOGY
Delay start
A period of time to elapse before controller starts a firing, for example, in order to make use of off-peak power.
Heating/Cooling Ramp
The rate of heating up or cooling down, usually expressed in number of degrees per hour, e.g. 150°C per hour. A kiln firing to 600°C at 150°C per hour would take 4 hours.
Set Point
Also called "Target temperature". The temperature at which the controller changes the ramp rate, starts to soak or switches off.For example a program might fire at 100°C per hour to the first set point of 600°C then fire at 250°C per hour to top temperature of 1120°C.
Soak or Dwell
The period of time that the kiln is held at a temperature in order to smooth out glazes or even out temperature in the kiln.Typically 15 to 20 minutes.
Segment
One part of the program, usually consisting of a ramp, a target temperature and a soak.
Event Relay
Output from a controller to operate an automatic damper, opening and closing it during the firing.


There are no downloads for this product.